Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Frame Material
Steel
C Face Kit
14-1401
Efficiency Group
Premium Efficient
Full Load Efficiency
94.5 %
Substitute Motor
M2549T
BALD Family Names
Premium Efficient, Nema Premium™
Epact Nominal Full Load Efficiency
93 %
Drive End Bearing
6313
Full Load Pf
91
Rotation
R
RPM
3600 rpm
RefPicture
ODP3P
Open End Bearing
6311
Voltage Rating
460, 230
Full Load rpm
3540 rpm
Brake Feature
No
Service Factor
1.15
Enclosure Designation
OPSB - Open Slotted Band
Design
B
Washdown Duty
No
Phase
Three Phase
C Dimension
27.56 in
Frame
364TS
Hz
60 Hz
Enclosure
OPSB
Useable at 208V
No
Type
4254M
Product Line
RG
Mult. Sym.
L1
Motor Shaft Size
1 7/8 in
VoltCode
F
Motor Shaft Length
3 3/4 in
Frame Size
Shaft Input, Not a C-Face
Motor Application
General Purpose
Mounting Style
F-1
Full Load Amps
82
Poles
2
Voltage
230/460
Mounting
Rigid Base
Weight
507.0 LB
EAN or UPC
781568105283
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back