Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
BALD Family Names
Premium Efficient, Nema Premium™
Mult. Sym.
L1
Efficiency Group
Premium Efficient
Frame Size
Shaft Input, Not a C-Face
Poles
4
Brake Feature
No
Full Load Efficiency
95 %
Useable at 208V
No
Open End Bearing
6311
Motor Shaft Length
5 7/8 in
RefPicture
ODP3P
Voltage Rating
575
Design
B
Frame
364T
Voltage
575
Product Line
RG
Type
4278M
C Dimension
29.69 in
Motor Application
General Purpose
Full Load rpm
1775 rpm
Enclosure Designation
OPSB - Open Slotted Band
VoltCode
H
Mounting Style
F-1
Mounting
Rigid Base
Motor Shaft Size
2 3/8 in
Full Load Pf
87
Washdown Duty
No
RPM
1800 rpm
Drive End Bearing
6313
Service Factor
1.15
Phase
Three Phase
Substitute Motor
M2547T-5
Rotation
R
Hz
60 Hz
Full Load Amps
56
Enclosure
OPSB
Weight
726.0 LB
EAN or UPC
781568118801
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back