Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Hz
60 Hz
Enclosure
TEFC
Full Load Pf
88
Mult. Sym.
L1
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Useable at 208V
No
BALD Family Names
Premium Efficient, Nema Premium™
Full Load Efficiency
91.7 %
Service Factor
1.15
Motor Shaft Size
1 5/8 in
RPM
3600 rpm
Poles
2
Full Load Amps
13.8
Brake Feature
No
Product Line
RG
Type
0934M
C Face Kit
09-1309
Frame
254T
C Dimension
23.19 in
Voltage
575
Motor Shaft Length
4 in
Frame Size
Shaft Input, Not a C-Face
Open End Bearing
6208
Motor Application
General Purpose
Washdown Duty
No
Drive End Bearing
6309
Mounting
Rigid Base
Phase
Three Phase
Frame Material
Cast Iron
Design
B
VoltCode
H
Mounting Style
F-1
Voltage Rating
575
Efficiency Group
Standard Efficient
RefPicture
EMTE
Rotation
R
Full Load rpm
3525 rpm
Weight
268.0 LB
EAN or UPC
781568138670
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back