Vickers D03 Solenoid Valve

02-309139

Vickers D03 Solenoid Valve
Item #102087856
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pilot Valve Type N/A
Coil Type Code F
Response Time 28 to 45 ms
Rated Flow [Max] 20 gal/min
Port T Code 7
Operation Solenoid Operated
Spool Spring Arrangement Code C
Center Position P Blocked, A & B to T
Port Restrictor Plug Code None
EN Code EN21
AC/DC DC
Seal Material Buna-N
Surge Suppressor/Damper None
Body Material Gray Iron
Pressure [Max] 5000 psi
Voltage & Frequency 24 VDC
Leakage Standard Performance
Reducer Module No
Response Type Standard Response
Mechanical Options None
Surge Suppressor/Damper Code None
Overrides No Overrides
Pilot/Drain None
Compatible Fluids Petroleum Oil
Coil Rating Code H
Port Restrictor Plugs None
Function Code 6
No. of Stages Single Stage
Fluid Cleanliness 19/17/14 micron
Temperature Range [Min] -4 °F
Tank Port Rating 3046
Electrical Options None
Model No. DG4V-3-6C-M-FW-H7-60-EN21
Solenoid Double
Indicator Lights No
Actuation Identification Solenoid A, Solenoid B
Function 3-Position Spring Centered
Temperature Range [Max] 158 °F
Mounting Subplate/Manifold Mount
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Code H
Manual Override Option Code None
NFPA Size D03
Electrical Connection No Connector
Manual Override Plain Override
Performance High Performance
Solenoid Indicator Lights Code None
Spool Shift Timing N/A
Spool Indicator Switch Code None
Cycle Rate [Max] N/A
Electrical Connector Code None
Housing Code W
Crossover P Blocked, A or B to T
Design No. 60
Solenoid Energization Code None
Watt Rating 30 W
Valve Type High-Performance
Pressure Port Check Valve Pressure N/A
Actuator Type Solenoid
Port T Pressure Rating 3000 psi
Spool Code 6
Weight 5.0 LB