Vickers by Danfoss02-363415

02-363415

Vickers D08 Solenoid Valve
Item #101906609
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-363415
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Electrical Connection No Connector
Actuator Type Solenoid
Pressure [Max] 5000 psi
EN Code None
Pilot Pressure Code None
Spool Code 0
Gauge Port SAE-4
Coil Rating Code B
Spool Indicator Switch Code None
Rated Flow [Max] 185 gal/min
Spool Control Modification Code None
Manual Override Option Code None
NFPA Size D08
Indicator Lights No
Electrical Options None
Operation Pilot Operated
Pressure Port Check Valve Code None
Valve Type Standard-Duty
Electrical Options Code None
Spool Spring Arrangement Code A
Pilot Drain Code None
Surge Suppressor/Damper Code None
Response Type Standard Response
Response Type Code None
Port Restrictor Plugs None
Tank Port Rating 5000
Solenoid Energization Code None
AC/DC AC
Solenoid Indicator Lights Code None
Surge Suppressor/Damper None
Model No. DG5V-8-H-0A-M-U-B-10
Housing Code None
Port Restrictor Plug Code None
Center Position All Ports Open
Mechanical Options None
Port T Pressure Rating 5000 psi
Crossover All Ports Open
Design No. 10
Electrical Connector Code None
Pressure Port Check Valve Pressure N/A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pilot Valve Type CETOP 3, High Performance
Reducer Module Code None
Pilot/Drain External Pilot/Internal Drain
Manual Override Plain Override
Coil Type DIN 43650
Gauge Ports Code None
Coil Type Code U
Reducer Module N/A
Pilot Valve Type Code H
Function 2-Position Spring Offset
Mechanical Options Code None
Overrides Plain Override Solenoid Ends
Solenoid Single
Seal Material Buna-N
Weight 35.0 LB